Heat Shrink Cable Terminations 3 Core up to 36kV for XLPE/EPR Insulated Cable (12-24-36kV)

Heat Shrink Cable Terminations 3 Core up to 36kV for XLPE/EPR Insulated Cable (12-24-36kV)

  1. All key inputs are produced in-house.
  2. Continuous operation temperature-55°C to 120°C.
  3. Corrosion resistant and unlimited shelf life.
  4. In compliance with HD629-1 & IEC-60502-4 / IS-13573.
  5. Lugs are optional. Compression or shear head mechanical lugs supplied on request.
Specifications

Heat Shrinkable Straight Through Terminations are Tested as per HD629-1 & IEC-60502-4 / IS:13573

Testing Items Uo/U/Um6.35/11/12 kV12.7/22/24 kV19/33/36 kV
A.C. withstand test28.5kV, 5min, no flashover57kV, 5min, no flashover85.5kV, 5min, no flashover
Partial discharge test12.5kV<10pc25kV<10pc38kV<10pc
Thermal Cycles (63 cycles)under 95-100°C 16kVunder 95-100°C 32kVunder 95-100°C 47.5kV
Impulse voltage test95kV no flashover125kV no flashover194kV no flashover
Humidity test (Indoor)No flashover, tracking
erosion or mechanical damage 
occured at 300hrs, 8kV
No flashover, tracking
erosion or mechanical damage 
occured at 300hrs, 16kV
No flashover, tracking
erosion or mechanical damage 
occured at 300hrs, 24kV
Salt Fog test (Outdoor)No flashover, tracking
erosion or mechanical damage
occured at 1000hrs, 8kV
No flashover, tracking
erosion or mechanical damage 
occured at 1000hrs, 16kV
No flashover, tracking
erosion or mechanical damage 
occured at 1000hrs, 24kV
Order Reference for Heat Shrink Terminations Indoor & Outdoor 3 Core
12 kV, 3 Core 
Indoor 
Terminations
Cable Cross 
Section (mm²)
Product Code
35 - 95AYDHSI-12 - 3 x 35-95
70 - 150AYDHSI-12 - 3 x 70-150
95 - 240AYDHSI-12 - 3 x 95-240
185 - 300AYDHSI-12 - 3 x 185-300
300 - 400AYDHSI-12 - 3 x 300-400
500AYDHSI-12 - 3 x 500
12 kV, 3 Core 
Outdoor 
Terminations
Cable Cross 
Section (mm²)
Product Code
35 - 95AYDHSO-12 - 3 x 35-95
70 - 150AYDHSO-12 - 3 x 70-150
95 - 240AYDHSO-12 - 3 x 95-240
185 - 300AYDHSO-12 - 3 x 185-300
300 - 400AYDHSO-12 - 3 x 300-400
500AYDHSO-12 - 3 x 500
24 kV, 3 Core 
Indoor 
Terminations
Cable Cross 
Section (mm²)
Product Code
35 - 95AYDHSI-24 - 3 x 35-95
70 - 150AYDHSI-24 - 3 x 70-150
95 - 240AYDHSI-24 - 3 x 95-240
185 - 300AYDHSI-24 - 3 x 185-300
300 - 400AYDHSI-24 - 3 x 300-400
500AYDHSI-24 - 3 x 500
24 kV, 3 Core 
Outdoor 
Terminations
Cable Cross 
Section (mm²)
Product Code
35 - 95AYDHSO-24 - 3 x 35-95
70 - 150AYDHSO-24 - 3 x 70-150
95 - 240AYDHSO-24 - 3 x 95-240
185 - 300AYDHSO-24 - 3 x 185-300
300 - 400AYDHSO-24 - 3 x 300-400
500AYDHSO-24 - 3 x 500
36 kV, 3 Core 
Indoor 
Terminations
Cable Cross 
Section (mm²)
Product Code
35 - 95AYDHSI-36 - 3 x 35-95
70 - 150AYDHSI-36 - 3 x 70-150
95 - 240AYDHSI-36 - 3 x 95-240
185 - 300AYDHSI-36 - 3 x 185-300
300 - 400AYDHSI-36 - 3 x 300-400
500AYDHSI-36 - 3 x 500
36 kV, 3 Core 
Outdoor 
Terminations
Cable Cross 
Section (mm²)
Product Code
35 - 95AYDHSO-36 - 3 x 35-95
70 - 150AYDHSO-36 - 3 x 70-150
95 - 240AYDHSO-36 - 3 x 95-240
185 - 300AYDHSO-36 - 3 x 185-300
300 - 400AYDHSO-36 - 3 x 300-400
500AYDHSO-36 - 3 x 500

Get in touch with 
AL YAMUNA DENSONS

Send us a message

Have a question, idea, or requirement? Drop us a message and our team will get back to you with clear answers no fluff, no delay.

Name
Email
Mobile No.
Company Name
Message